发布者:admin  发布时间:2012-7-2 14:30:31  点击:5019

罐组内的储罐不该超过两排;柴油罐但单罐容积小于或就是1000m3的丙B类的储罐不该超越4排,两排立式储罐的间距应合适表6.2.8的规则,且不该小于5m;两排直径小于5m的立式储罐及卧式储罐的间距不应小罐组应布防 立式储罐至防火堤内堤脚线的隔断不该小于罐壁高度的一半,卧式储罐至防火堤内堤脚线的距离不应小于3m。相邻罐组防火堤的外堤脚线之间应留有宽度不小于7m的消防空隙设有防火堤的罐组内应按以下申请设置装备摆设隔堤:多种类的液体罐组内应按下列要求配置防火堤及隔堤应相符以下规 事件存液池的设置应相符下列规设有事情存液池的罐组应设导液管(沟),使溢漏液体能顺利地流出罐组并自流入存液池内事变存液池距防火堤的距离不应小于事项存液池和导液沟距明火所在不应小于30 变乱存液池应有排水设施 甲B、乙类液体的固定顶罐应设阻兵器和呼吸阀;关于采纳氮气或其它气体气封的甲B、乙类液体的储罐还应设置事变泄压装备。常压固定顶罐顶板与包边角钢之间的毗连应采用弱顶结 储存温度高于100℃的丙B类液体储罐应设专门使用扫 设有蒸汽加热器的储罐应采取避免液体超温的措可燃液体的储罐宜设积极脱水器,并应设液位计和高液位报警器,须要时可设踊跃联锁割断进料设 储罐的进料管应从罐体下部接入;若必须从上部接入,宜皱缩至距罐底200妹妹处。储罐的进入口管道应采用柔性毗连。气温通常为35℃,或许采取一些冷却按次。(图/文http://www.wxfengli.com/
(中译英)
Tank group within the tank should not exceed two rows; but the volume of a single tank is less than or is a 1000m3C B class tank should not exceed 4rows, two rows of vertical storage tank spacing should be suitable for table 6.2.8rules, and should not be less than5m diameter less than 5m; two rows of vertical storage tank and horizontal storage space should a group should be deployed tanks to fire bank toe line partition should not be less than half of the height of the tank wall, horizontal storage tank to fire bank toe line distance shall be not less than3m. Adjacent tank fire dike outer toe the line should have a width not less than7m fire with fire dike gap tank group should according to the following application equipment Bank: many types of liquid tank should be according to the following requirements should be consistent configuration of fire wall and bank regulation events following liquid storage pool settings should conform to the following requirements set things liquid storage pool tank group should set up the liquid guide tube ( ditch), so that the spill liquid can smoothly out of the tank group and is gravity fed to the liquid storage pool within the incident from the liquid storage pool fire distance shall be not less than the matter of liquid storage pool and a liquid guide groove from the fire place should not be less than 30. The liquid storage pool drainage facilities of B, liquid B fixed roof tank should be set resistance weapons and breathing valve; on the adoption of nitrogen or other gases air sealed a B, B type liquid storage tank should be set emergency pressure relief equipment. Atmospheric fixed roof tank roof and edge angle between abutting should adopt weak roof node storage temperature higher than 100 DEG C B type liquid storage tank should be devoted to the use of a steam heater and storage tank should be taken to avoid the liquid temperature.

上一页:如果汽油罐里有异味怎么办
下一页:沥青罐里的沥青是凝固的